/content/advancedmaterials/us/en/search-results.html

Genetron® HFCs

Genetron® 407C - (R-407C)

A long-term, non-ozone depleting replacement for R-22 in various air-conditioning applications as well as in positive displacement refrigeration systems. For new equipment and retrofits. Not recommended for use in chillers with a flooded evaporator.

Overview
A long-term, non-ozone depleting replacement for R-22 in various air-conditioning applications as well as in positive displacement refrigeration systems. For new equipment and retrofits. Not recommended for use in chillers with a flooded evaporator.Search SDS Number in SDS Finder - 09894
Specifications

General Information

  • Application
    • Commercial A/C
    • Commercial Refrigeration
    • Residential A/C
    • Retrofit
  • ASHRAE Number
    • R-407C
  • Brand
    • Genetron®
  • Chemical Name
    • Difluoromethane
    • Pentafluoroethane
    • Tetrafluoroethane
  • Contains
    • HFC-32 (23%), HFC-125 (25%), HFC-134a (52%)
  • Glide
    • High
  • Linear Formula
    • CH2F, CF3CHF2, CF3CH2F
  • Refrigerant Class
    • HFC
  • Refrigerant Type
    • Blend
  • Substitutes
    • HCFC-22
  • Typical Lubricant
    • POE

Physical Properties

  • Critical Pressure
    • 671.49 psia
  • Molecular Weight
    • 86.2 lbm/lbmol
  • Saturated Liquid Density
    • 69.6 lb/ft3 at 86 °F
  • Specific Heat of Liquid
    • 0.38 Btu/lb at 86 °F
  • Specific Heat of Vapor
    • 0.18 Btu/lb at 86 °F and 1 Atm, at Cp

Temperature

  • Boiling Point/Range
    • -46.5 °F at 1 Atm
  • Critical Temperature
    • 186.86 °F (ASTM D-1321)
  • Freezing Point
    • -256 °F at 1 Atm

Safety & Environment

  • Flammable Range
    • None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • Global Warming Potential
    • 1774

Standards & Approvals

  • ASHRAE Safety Classification
    • A1

General Information

  • Application
    • Commercial A/C
    • Commercial Refrigeration
    • Residential A/C
    • Retrofit
  • ASHRAE Number
    • R-407C
  • Brand
    • Genetron®
  • Chemical Name
    • Difluoromethane
    • Pentafluoroethane
    • Tetrafluoroethane
  • Contains
    • HFC-32 (23%), HFC-125 (25%), HFC-134a (52%)
  • Glide
    • High
  • Linear Formula
    • CH2F, CF3CHF2, CF3CH2F
  • Refrigerant Class
    • HFC
  • Refrigerant Type
    • Blend
  • Substitutes
    • HCFC-22
  • Typical Lubricant
    • POE

Physical Properties

  • Critical Pressure
    • 671.49 psia
  • Molecular Weight
    • 86.2 lbm/lbmol
  • Saturated Liquid Density
    • 69.6 lb/ft3 at 86 °F
  • Specific Heat of Liquid
    • 0.38 Btu/lb at 86 °F
  • Specific Heat of Vapor
    • 0.18 Btu/lb at 86 °F and 1 Atm, at Cp

Temperature

  • Boiling Point/Range
    • -46.5 °F at 1 Atm
  • Critical Temperature
    • 186.86 °F (ASTM D-1321)
  • Freezing Point
    • -256 °F at 1 Atm

Safety & Environment

  • Flammable Range
    • None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • Global Warming Potential
    • 1774

Standards & Approvals

  • ASHRAE Safety Classification
    • A1
  • Chemical Name : Difluoromethane|Pentafluoroethane|Tetrafluoroethane
  • Contains : HFC-32 (23%), HFC-125 (25%), HFC-134a (52%)
  • Typical Lubricant : POE
  • Glide : High
  • ASHRAE Number : R-407C
  • Refrigerant Class : HFC
  • Linear Formula : CH2F, CF3CHF2, CF3CH2F
  • Brand : Genetron®
  • Application : Commercial A/C|Commercial Refrigeration|Residential A/C|Retrofit
  • Substitutes : HCFC-22
  • Refrigerant Type : Blend
  • Saturated Liquid Density : 69.6 lb/ft3 at 86 °F
  • Critical Pressure : 671.49 psia
  • Specific Heat of Liquid : 0.38 Btu/lb at 86 °F
  • Molecular Weight : 86.2 lbm/lbmol
  • Specific Heat of Vapor : 0.18 Btu/lb at 86 °F and 1 Atm, at Cp
  • Critical Temperature : 186.86 °F (ASTM D-1321)
  • Boiling Point/Range : -46.5 °F at 1 Atm
  • Freezing Point : -256 °F at 1 Atm
  • Global Warming Potential : 1774
  • Flammable Range : None, %vol. in air (Based on ASHRAE Standard 34 with Match Ignition)
  • ASHRAE Safety Classification : A1
Others
Name
Description
File Size
Date
Size
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 03 rev 0.0
application/pdf 85.49 KB
1/24/2024
85.49 KB
Technical Bulletin Product: Refrigerant blends with glide (R-400 series) Bulletin#: 07 rev 1.0
application/pdf 133.91 KB
1/24/2024
133.91 KB
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 04 rev 0.0
application/pdf 126.18 KB
1/24/2024
126.18 KB
Technical Bulletin. Refrigerant blends with glide (R-400 series) Bulletin#: 12.0 rev 0.0
application/pdf 215.9 KB
1/24/2024
215.9 KB
Name
Description
File Size
Date
Size
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 03 rev 0.0
application/pdf 85.49 KB
1/24/2024
85.49 KB
Technical Bulletin Product: Refrigerant blends with glide (R-400 series) Bulletin#: 07 rev 1.0
application/pdf 133.91 KB
1/24/2024
133.91 KB
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 04 rev 0.0
application/pdf 126.18 KB
1/24/2024
126.18 KB
Technical Bulletin. Refrigerant blends with glide (R-400 series) Bulletin#: 12.0 rev 0.0
application/pdf 215.9 KB
1/24/2024
215.9 KB
Name
Description
File Size
Date
Size
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 03 rev 0.0
85.49 KB
1/24/2024
Technical Bulletin Product: Refrigerant blends with glide (R-400 series) Bulletin#: 07 rev 1.0
133.91 KB
1/24/2024
Technical Bulletin. Product: Refrigerant Blends with glide (R-400 series). Bulletin#: 04 rev 0.0
126.18 KB
1/24/2024
Technical Bulletin. Refrigerant blends with glide (R-400 series) Bulletin#: 12.0 rev 0.0
215.9 KB
1/24/2024